Installation and Operating Instructions
190 Alarm Operation
NOTE: The Time Sync Signal (Alarm In 17) is used to reset the system time of the
Intellex to the nearest hour. If the Intellex system time is up to 30 minutes
before the hour, the system time is set forward to the next hour (at zero
minutes and zero seconds). If the Intellex system time is up to 30 minutes
after the hour, the system time is set back to the previous hour (at zero
minutes and zero seconds).
NOTE: The Export Signal input (Alarm In 18) can be used to start a Fill CD operation
without access to the normal user interface. A contact closure, e.g., an
external switch, can be used to execute the Fill CD command to export the
last 500 MB of data to a CD. See Selective Export on page 160.
5 Input 5 5 Output 5
G Ground G Ground
6 Input 6 6 Output 6
G Ground G Ground
7 Input 7 7 Output 7
G Ground G Ground
8 Input 8 8 Output 8
G Ground G Ground
16 Time sync signal 16 Output 16 (Unit Alarm)
G Ground G Ground
18 Export signal COM Reserved
G Ground NO Reserved