Intellex RMS Digital Video Management System
Setup Options 91
Select another segment for configuration. Otherwise, click OK to accept the
configuration for this segment as shown, and return to the Weekday, Weekend or
Holiday screen. Click Cancel to cancel the changes. Click Help to display online help
for this screen.
Pre-Alarm Sensitivity This setting lets you control how Intellex responds to
small, subtle changes between images. Select the
sensitivity to use when storing pre-alarm images. The
default is Normal.
High At this setting, Intellex records the
smaller changes between images,
improving the perceived picture
quality. As a result, this setting
requires more storage space.
Normal At this setting, Intellex ignores the
smaller, more subtle changes
between images.
Live Filter Use this option to select the live filter to use during this
segment. When the live filter is activated, the unit
switches to alarm mode. The default is None.
NOTE: Before you can configure a live filter, you must
record at least one image from the camera. Until
an image is recorded, the filter options are
disabled.
Setup Select a filter for this segment; then
click Setup to configure it (see Live
Filter Configuration on page 92).
Pre-Alarm Duration The unit continuously saves pre-alarm images for each
camera, up to the pre-alarm duration. When an event
occurs, the unit records these images to the image
database. The default is 15 Seconds.