5-10 View Manager 96 Operator’s Manual
Now that the highest numbered alarming monitor is sequencing alarms, its
Workstation indicator type changes fromW1-M5A” to “W1-M5S”. This
indicates that this monitor is sequencing more than one alarm. In addition, it
also displays the number of alarms that are currently stored in its queue.
This is indicated by the characters “Q:X”, where X is the number of alarms in
the queue. The alarm queue indicator is displayed below the alarm count
indicator.
W1-M1G
A:12
W1-M2A
ALMS:4
A:7
W1-M3A
ALMS:4
W1-M4G
ALMS:4
Q:2
A:22
W1-M5S W1-M6G
Figure 5-6: Workstation with four active alarms. Alarms are sequenced on Monitor 5.
As alarms come into the system, they sequence on the highest numbered
alarming monitor. The general monitors always remain unaffected by alarms.
Figure 5-7 shows how the system handles six active alarms in a Workstation
that has only three alarming monitors.
Monitor 3 Monitor 2 Monitor 1
Workstation 1: Four Alarms
Monitor 6 Monitor 5 Monitor 4
Monitor 5 is now sequencing
the third and fourth alarms.